Modeldisambiguationenabled – Adept AdeptSight Reference Guide User Manual
Page 354

ModelDisambiguationEnabled
VPARAMETER
403
When set to True (default), the Locator applies disambiguation to discriminate between similar models and
between similar hypotheses of a single object. When set to False, the Locator does not apply
disambiguation.
Syntax
MicroV+
VPARAMETER (sequence_id, tool_id, 403, index_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 403, index_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 403, index_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 403, index_id, object_id)
Type
Boolean
Range
Value
Description
1
Locator applies disambiguation.
0
Locator does not apply disambiguation.
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
ModelDisambiguationEnabled
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012