MinimumLinePercentage
VPARAMETER
5130
Minimum percentage of line contours that need to be matched for a line hypothesis to be considered as
valid.
Syntax
MicroV+
VPARAMETER (sequence_id, tool_id, 5130, index_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 5130, index_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 5130, index_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 5130, index_id, object_id)
Type
Double
Range
Minimum: 0.1
Maximum: 100.0
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
ID
5130: the value used to reference this property.
index_id
N/A
object_id
N/A