Inspectionfilterpassstatus – Adept AdeptSight Reference Guide User Manual
Page 259
V+
value = VRESULT ($ip, sequence_id, tool_id, instance_id, 2701, index_id)
Type
Long
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
instance_id
Index of the instance for which you want the result.
ID
2701: the value used to reference this property.
index_id
The filter index you want returned.
InspectionFilterPassStatus
VRESULT
2702
The code returns the pass status of the specified filter for the instance. Read only.
Syntax
Micro V+
value = VRESULT (sequence_id, tool_id, instance_id, 2702, index_id)
V+
value = VRESULT ($ip, sequence_id, tool_id, instance_id, 2702, index_id)
Type
Long
Parameters
ImageWidth
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012
Page 259