Greylevelrange – Adept AdeptSight Reference Guide User Manual
Page 231

GreylevelRange
VRESULT
1508
Range of greylevel values of the pixels in the tool's region of interest that are included in the final
histogram. Pixels removed from the histogram by tails or thresholds are not included in this calculation.
The range is equal to MaximumGreylevelValue - MinimumGreylevelValue + 1. Read only.
Syntax
Micro V+
value = VRESULT (sequence_id, tool_id, instance_id, 1508, index_id, frame_id)
V+
value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1508, index_id, frame_id)
Type
Long
Range
Minimum: 0
Maximum: 256
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard
IP address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
instance_id
Index of the instance for which you want the result.
ID
1508: the value used to reference this property.
index_id
The index of the frame for which you want to set the mode.
frame_id
N/A
GreylevelRange
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012
Page 231