Candidatepointscount – Adept AdeptSight Reference Guide User Manual
Page 123

CandidatePointsCount
VPARAMETER
5300
Sets the number of candidate locations where the tool tries to evaluate the sharpness. When the tool is
executed, it scans the region of interest and identifies a number of candidate locations (equal to
CandidatePointsCount) where the local standard deviation is the highest. The local sharpness is then
evaluated at each of the candidate location that has a local standard deviation above
StandardDeviationThreshold. The number of locations where the sharpness is actually measured is
returned by the MeasurementPointsCount property. When the AutomaticCandidateCountEnabled
property is True, the number of candidate measurement points is determined automatically according to
the size of the region of interest and CandidatePointsCount.
Syntax
Micro V+
VPARAMETER (sequence_id, tool_id, 5300, index_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 5300, index_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 5300, index_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 5300, index_id, object_id)
Type
Long
Range
Minimum: Greater than 0.
Maximum: 32767
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
CandidatePointsCount
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012