PairSize
VRESULT
1925
Score of the selected pair. The score of the pair is equal to the mean score of the two edges (Edge1Score
and Edge2Score) that comprise the pair. Read only.
Syntax
Micro V+
value = VRESULT (sequence_id, tool_id, instance_id, 1925, index_id, frame_id)
V+
value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1925, index_id, frame_id)
Type
Double
Range
Greater than 0.
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses
standard IP address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
instance_id
Index of the pair for which you want the result.
ID
1925: the value used to reference this property.
index_id
N/A
frame_id
Frame containing the pair.
PairSize