beautypg.com

Minimumclearpercentageenabled – Adept AdeptSight Reference Guide User Manual

Page 345

background image

MinimumClearPercentageEnabled

VPARAMETER

558

When MinimumClearPercentageEnabled is set to true, the MinimumClearPercentage constraint is applied

to the search process.

Syntax

MicroV+

VPARAMETER (sequence_id, tool_id, 558, index_id, object_id) = value

value = VPARAMETER (sequence_id, tool_id, 558, index_id, object_id)

V+

VPARAMETER (sequence_id, tool_id, 558, index_id, object_id) $ip = value

value = VPARAMETER ($ip, sequence_id, tool_id, 558, index_id, object_id)

Type

Boolean

Range

Value

Description

1

The MinimumClearPercentage constraint is enabled and applied to the Search process.

0

The MinimumClearPercentage constraint is not enabled.

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP

address format, for example: 192.168.1.120.

sequence_id

Index of the vision sequence. The first sequence is 1.

tool_id

Index of the tool in the vision sequence. The first tool is 1.

ID

558: the value used to reference this property.

index_id

N/A

object_id

N/A

MinimumClearPercentageEnabled

AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012

Page 345