Filterhuetolerance – Adept AdeptSight Reference Guide User Manual
Page 202

FilterHueTolerance
VPARAMETER
5716
Value of the tolerance allowed for Hue value defined by FilterHueValue, for the selected filter. The
FilterHueTolerance value is distributed equally above and below the FilterHueValue.
For example, if FilterLuminanceValue = 200 and FilterHueTolerance = 20, the filter will accept pixels
with a range of hue values = [190,200].
Syntax
Micro V+
VPARAMETER (sequence_id, tool_id, 5716, filter_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 5716, filter_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 5716, filter_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 5716, filter_id, object_id)
Remarks
When FilterHueTolerance = 1, no tolerance (variation) in luminance is accepted. The filter will only
accept pixels with a luminance value equal to FilterHueValue.
Type
Long
Range
Minimum: 1
Maximum: 128
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
FilterHueTolerance
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012
Page 202