InstanceFitQuality
VRESULT
1317
Normalized average error between the matched model contours of the selected object instance and the
actual contours detected in the input image. Fit quality ranges from 0 to 1, with 1 being the best quality. A
value of 1 means that the average error is 0. Conversely, a value of 0 means that the average matched
error is equal to conformity tolerance. Read only.
Syntax
MicroV+
value = VRESULT (sequence_id, tool_id, instance_id, 1317, index_id, frame_id)
V+
value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1317, index_id, frame_id)
Remarks
Index of frame that contains the specified instance. Range: [1, ResultCount -1]
Type
Double
Range
Minimum: 0.0
Maximum: 1.0
Parameters
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
instance_id
Index of the instance for which you want the result.
ID
1317: the value used to reference this property.
index_id
N/A
InstanceFitQuality
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012