Paircount – Adept AdeptSight Reference Guide User Manual
Page 388
![background image](https://www.manualsdir.com/files/771277/content/doc388.png)
PairCount
VPARAMETER
1920
PairCount indicates the number of pairs that have configured for the tool. Read only.
Syntax
Micro V+
value = VPARAMETER (sequence_id, tool_id, 1920, index_id, object_id)
V+
value = VPARAMETER ($ip, sequence_id, tool_id, 1920, index_id, object_id)
Remarks
If an edge pair is not found, results for this edge pair appear as zero, but the PairCount property is not
affected. To get the number of pairs found by the tool use the ResultCount property.
Type
Long
Range
Minimum: 0
Maximum: Unlimited
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses
standard IP address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
instance_id
Index of the instance for which you want the result.
ID
1920: the value used to reference this property.
index_id
N/A
frame_id
N/A
PairCount
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012