GripperInputOpen

VPARAMETER

5514

Returns the open input signal for a given tip on the gripper. Read only.

Syntax

MicroV+

value = VPARAMETER (sequence_id, tool_id, 5514, index_id, object_id)

V+

value = VPARAMETER ($ip, sequence_id, tool_id, 5514, index_id, object_id)

Type

Real variable.

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP address

format, for example: 192.168.1.120.

sequence_id

Should always be set to -1.

tool_id

The tip number.

ID

5514: the value used to reference this property.

index_id

The robot number.

object_id

The index of the signal number to access.

GripperInputOpen

AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012