VPARAMETER program instruction
NOTE: This keyword can also be used to control the Adept AnyFeeder. For details, see the
, Rev B or later.
Syntax
MicroV+
VPARAMETER
(sequence_id, tool_id, parameter_id, index_id, object_id) = value
V+
VPARAMETER
(sequence_id, tool_id, parameter_id, index_id, object_id)
$ip
= value
Description
Sets the current value of a vision tool parameter.
Parameters
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
parameter_id
Identifier (ID) of the parameter. Refer to the AdeptSight Properties Quick
Reference tables to find the ID for the required parameter.
index_id
Reserved for internal use. Value is always 1.
object_id
Some parameters require an object index to access specific values in an array.
Please refer to the details for the individual parameter to understand the
meaning and possible usage.
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
Details
The following parameters are optional: sequence_id, tool_id, parameter_id, index_id, and object_id.
These parameters are 1-based. If no value is provided for these parameters, they default to 1.
For V+ systems, the vision server is the PC on which the AdeptSight vision software is running.
Example
VPARAMETER program instruction