MaximumInstanceCountEnabled
VPARAMETER
518
When MaximumInstanceCountEnabled is True, the search is limited to the number of instances set by
the MaximumInstanceCount property
Syntax
MicroV+
VPARAMETER (sequence_id, tool_id, 518, index_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 518, index_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 518, index_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 518, index_id, object_id)
Type
Long
Range
Value
Description
1
Search is limited to number of instances specified by MaximumInstanceCount.
0
Search is not limited to a set number of instances.
Parameters
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
ID
518: the value used to reference this property.
index_id
N/A
object_id
N/A
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
MaximumInstanceCountEnabled
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012