Calibratedunitsenabled – Adept AdeptSight Reference Guide User Manual
Page 122

CalibratedUnitsEnabled
VPARAMETER
103
Returns 1 if the image the virtual camera image the tool is operating on has an active calibration applied. If
no calibration is in effect, a 0 is returned. Read only.
Syntax
MicroV+
value = VPARAMETER (sequence_id, tool_id, 103, index_id, object_id)
V+
value = VPARAMETER ($ip, sequence_id, tool_id, 103, index_id, object_id)
Type
Boolean
Range
Value
Description
1
Dimensions are expressed in millimeters. (Default)
0
Dimensions are expressed in pixel units.
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
ID
103: the value used to reference this property.
index_id
N/A
object_id
N/A
CalibratedUnitsEnabled
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012