Maximuminstancecount – Adept AdeptSight Reference Guide User Manual
Page 334

MaximumInstanceCount
VPARAMETER
519
Maximum number of object instances that are searched for in the input grey-scale Image. All of the object
instances respecting the search constraints are output, up to a maximum of MaximumInstanceCount.
They are ordered according to the InstanceOrdering property.
Syntax
MicroV+
VPARAMETER (sequence_id, tool_id, 519, index_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 519, index_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 519, index_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 519, index_id, object_id)
Remarks
This property is applicable only if the MaximumInstanceCountEnabled property is set to True.
Type
Double
Range
Minimum: 1
Maximum: 2000
Parameter
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
ID
519: the value used to reference this property.
index_id
N/A
MaximumInstanceCount
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012