Minimumarcpercentage – Adept AdeptSight Reference Guide User Manual
Page 342
MinimumArcPercentage
VPARAMETER
5142
Minimum percentage of arc contours that need to be matched for an arc hypothesis to be considered as
valid.
Syntax
MicroV+
VPARAMETER (sequence_id, tool_id, 5142, index_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 5142, index_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 5142, index_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 5142, index_id, object_id)
Type
Double
Range
Minimum: 1
Maximum: 100.0
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
ID
5142: the value used to reference this property.
index_id
N/A
object_id
N/A
MinimumArcPercentage
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012
Page 342