MeasurementPointsCount
VRESULT
2002
The number of points where the local sharpness is evaluated. When the Image Sharpness tool is executed,
it scans the region of interest and identifies a number of candidate locations (equal to
CandidatePointsCount) where the local standard deviation is the highest. The local sharpness is then
evaluated at each of the candidate locations that has a local standard deviation above
StandardDeviationThreshold. Read only.
Syntax
Micro V+
value = VRESULT (sequence_id, tool_id, instance_id, 2002, index_id, frame_id)
V+
value = VRESULT ($ip, sequence_id, tool_id, instance_id, 2002, index_id, frame_id)
Type
Long
Range
Minimum: 0
Maximum: CandidatePointsCount
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
ID
2002: the value used to reference this property.
index_id
N/A
object_id
N/A
MeasurementPointsCount
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012