If the -burnin option is used, a set of tests, known as the test subset, is repeated continuously for a
period of time. The default test period is two hours and the default subset is:

-memory

-ping

-throughput

-traffic

-cryptoaccel

The duration of the -burnin test can be changed, as can the test subset. For example, a test of the
memory and media that is repeated for 30 minutes would be:

Device:/> selftest -burnin -minutes=30 -memory -media

The -burnin option could, for example, be used to detect errors that only occur sporadically or
possibly only occur after some hardware component has reached a certain critical operating
temperature.

The full list of options for selftest CLI command can be found in the CLI Reference Guide along with
more command line examples.