Memory monitoring settings – Amer Networks E5Web GUI User Manual
Page 105

•
2 - PSU inserted, powered up.
2.4.6. Memory Monitoring Settings
The System > Device > Hardware Monitoring section of the Web Interface or InControl
provides the administrator with a number of settings related to the monitoring of available
memory. These are:
Memory Poll Interval
Memory polling interval which is the delay in minutes between readings of memory values.
Minimum 1, Maximum 200.
Default: 15 minutes
Memory Use Percentage
True if the memory monitor uses a percentage as the unit for monitoring, False if megabytes are
used. Applies to Alert Level, Critical Level and Warning Level.
Default: True
Memory Log Repetition
Should we send a log message for each poll result that is in the Alert, Critical or Warning level, or
should we only send when a new level is reached. If True, a message is sent each time Memory
Poll Interval is triggered. If False, a message is sent when a value goes from one level to another.
Default: False
Alert Level
Generate an Alert log message if free memory is below this number of bytes. Disable by setting
to 0. Maximum value is 10,000.
Default: 0
Critical Level
Generate a Critical log message if free memory is below this number of bytes. Disable by setting
to 0. Maximum value is 10,000.
Default: 0
Warning Level
Generate a Warning log message if free memory is below this number of bytes. Disable by
setting to 0. Maximum value 10,000.
Default: 0
Chapter 2: Management and Maintenance
105