2 - PSU inserted, powered up.

2.4.6. Memory Monitoring Settings

The System > Device > Hardware Monitoring section of the Web Interface or InControl
provides the administrator with a number of settings related to the monitoring of available
memory. These are:

Memory Poll Interval

Memory polling interval which is the delay in minutes between readings of memory values.
Minimum 1, Maximum 200.

Default: 15 minutes

Memory Use Percentage

True if the memory monitor uses a percentage as the unit for monitoring, False if megabytes are
used. Applies to Alert Level, Critical Level and Warning Level.

Default: True

Memory Log Repetition

Should we send a log message for each poll result that is in the Alert, Critical or Warning level, or
should we only send when a new level is reached. If True, a message is sent each time Memory
Poll Interval is triggered. If False, a message is sent when a value goes from one level to another.

Default: False

Alert Level

Generate an Alert log message if free memory is below this number of bytes. Disable by setting
to 0. Maximum value is 10,000.

Default: 0

Critical Level

Generate a Critical log message if free memory is below this number of bytes. Disable by setting
to 0. Maximum value is 10,000.

Default: 0

Warning Level

Generate a Warning log message if free memory is below this number of bytes. Disable by
setting to 0. Maximum value 10,000.

Default: 0