Table 2-35. Ku-Band ODU Specifications (Continued)

Parameter

Specifications

Environmental:

Shock

The unit will pass data without SYNC loss at 64 kbit/s, QPSK 1/2 rate
when subjected to a shock of 10g’s at 10 sec (half sine) on x, y, and z
axes. The unit will survive a shock of 40g’s at 10msec on x, y, and z
axes in non-operating mode.

Note: Without mounting cradle.

Vibration

The unit will pass data without SYNC loss at 64 kbit/s, QPSK 1/2 rate
when exposed to 10 minutes per axis plus 5 minute resonant dwell at
four major resonance’s per axis at a level of 1.0g (0-Peak), and to
2.41 G

rms

(approx.) of random vibration specified as follows:

Frequency

Slope

PSD

5 to 100 Hz

0

0.020 g

2

/Hz

100 to 137 Hz

-6 dB/oct

-

137 to 350 Hz

0

0.0107 g

2

/Hz

350 to 500 Hz

-6 dB/oct

-

500 Hz

-

0.0052g

2

/Hz

The unit will survive vibration during transportation as follows:
5 to 200 Hz at 1.5 peak sinusoidal acceleration in shipping container.