C5/K1/K3 Integrated Satellite Terminal System

Remote Control Operation

Rev. 0

B–19

Demodulator/
Decoder
Configuration
Program
Status

Command:
Response:

>add/DCP_'cr'
SMT_xxxxxx'cr'
IROT_xxxxx'cr'
MOM_xxxxxxx'cr'
BERT_xxxx'cr'
DT_xxxx'cr'
DDT_xxx'cr'

Ku-Band:
DB_x'cr'

C-Band
DF_n.nnnnnnn'cr'

Ku-Band::
DF_nn.nnnnnnn'cr'
DR_nnnn_mmmm.mmm'cr'
DE_xxx'cr'
DDEC_xxx'cr'
RFL_xxx'cr'
IFL_xxx'cr'
SCF_snnnnn'cr'
SWR_nnnnn'cr'
SR_xxx'cr'
ERF_nnnnn.n'cr'
BC_xxx'cr'
RCP_xxxx'cr'
BBL_xxx'cr'
ILB_xxx'cr'
ILT_xxx'cr'
ICFR_xxxx'cr'
IRFS_T1_ssss'cr'
IRFS_E1_ssss'cr'
IBP_xxx'cr'
IRE_xxxx'cr'
RDF_xxxx'cr'
RDP_xxxx'cr'
IBS_nnnnnn'cr'
DSR_xxx'cr'
RSDE_xxx'cr'
RXDR_xxxxxx'cr'
ROBR_nnnnn'cr'

(See Note)

RCCL_n'cr' Length

(See Note)

RCSB_n'cr'

(See Note)

ROCP_xxxx'cr'

(See Note)

RCT_xxxxx'cr'

(See Note)

ENSP_nn. (See

Note)

MAXT_n.n'cr'

(See Note)

RDA_xxx'cr''lf']

System Modem Type
Interface Receive Overhead Type
Modem Operation Mode
BER Threshold
Demodulator Type
Demodulator Decoder Type

Ku-Band:
Demodulator Band

C-Band:
Demodulator Frequency

Ku-Band:
Demodulator Frequency
Demodulator Rate
Descrambler Enable
Differential Decoder
RF Loopback
IF Loopback
Sweep Center Frequency
Sweep Width Range
Sweep Reacquisition
External Reference Frequency
Buffer Clock
Receive Clock Phase
Baseband Loopback
Interface Loop Back
Interface Loop Timing
Interface Coding Format Receive
Interface Receive T1 Frame Structure
Interface Receive E1 Frame Structure
Interface Buffer Programming
Interface Read Error (RX 2047)
Receive Data Fault
Receive Data Phase
Interface Buffer Size
Demodulator Spectrum Rotation
Reed-Solomon Decoder
RX Driver Type
ASYNC Receive Overhead Baud Rate
ASYNC Receive Channel Character Length
ASYNC Receive Channel Stop Bits
ASYNC Receive Overhead Channel Parity
ASYNC Receive Communications Type
AUPC EBN0 Target Set Point
AUPC Maximum Tracking Rate
Receive BPSK Data Ordering

This command is used by the EF Data M:N protection switch to
collect information that is necessary to configure back-up
modems. Because this command (content and/or order) can
be changed at any time by EF Data, it is advisable that other
commands ('DCS_' and 'ICS_', or 'BCS_') be used for M&C
systems.

Note: Data is only returned for RX ASYNC Overhead.

This manual is related to the following products: