Automatic Uplink Power Control (AUPC) Configuration
Commands
AUPC Local
Enable
(ASYNC
Overhead
only)
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.
Note: When programmed ON, the MOP (Modulator Output
Power) command is not allowed, only MOP status is allowed.
AUPC
Nominal
Power Level
(ASYNC
Overhead
only)
Command:
Response:
Status:
Response:
C-Band:
Where: snn.n = +25.0 to +38.0 in 0.1 steps (nominal
range in dBm).
K1 Ku-Band:
Where: snn.n = +17.0 to +30.0 in 0.1 steps (nominal
range in dBm).
K3 Ku-Band:
Where: snn.n = +22.0 to +35.0 in 0.1 steps (nominal
range in dBm).
AUPC
Maximum
Power Limit
(ASYNC
Overhead
only)
Command:
Response:
Status:
Response:
C-Band:
Where: snn.n = +25.0 to +38.0 in 0.1 steps (nominal
range in dBm).
K1 Ku-Band:
Where: snn.n = +17.0 to +30.0 in 0.1 steps (nominal
range in dBm).
K3 Ku-Band:
Where: snn.n = +22.0 to +35.0 in 0.1 steps (nominal
range in dBm).
AUPC
Minimum
Power Limit
(ASYNC
Overhead
only)
Command:
Response:
Status:
Response:
C-Band:
Where: snn.n = +25.0 to +38.0 in 0.1 steps (nominal
range in dBm).
K1 Ku-Band:
Where: snn.n = +17.0 to +30.0 in 0.1 steps (nominal
range in dBm).
K3 Ku-Band:
Where: snn.n = +22.0 to +35.0 in 0.1 steps (nominal
range in dBm).
AUPC
Eb/N0
Target Set
Point
(ASYNC
Overhead
only)
Command:
Response:
Status:
Response:
Where: nn.n = 3.2 to 16.0 in .1 increments (Eb/N0 in dB).
AUPC
Maximum
Tracking
Rate
(ASYNC
Overhead
only)
Command:
Response:
Status:
Response:
Where: n.n = 0.5 to 6.0 in .5 increments (Max tracking rate in
dBm/minute).