Operation
Rev. 0
4–33
4.1.3.8 Faults/Alarms
Refer to Figure 4-11.
The Faults/Alarms menu is accessible from the Function Select menu. The Faults/Alarms
are similar to monitor functions, as they display the current fault status of the group being
displayed.
Press
[
"] or [#] to move between the following Faults/Alarms groups:
! Modulator
! Demodulator
! Transmit Interface
! Receive Interface
! Common Equipment
Line 2 of the display shows the current Faults/Alarms status in real time. For each
parameter monitored, fault status is displayed as one of the following:
! “–” indicates that no fault or alarm exists.
! “+” indicates that a fault exists, and will cause switching in a redundant system.
! Reversed contrast “+” indicates an active alarm.
Unlike faults, alarms do not cause switching to occur. To display labels for individual
faults or alarms, press [ENTER].
Press [
"] or [#] to move the flashing cursor to make the selection. The label for that
Fault/Alarm is then displayed on line 1 of the display. Press [CLEAR] to exit this level of
operation and return to the previous level.
The following sections outline the faults and alarms monitored and displayed in each
group.