beautypg.com

Comtech EF Data C5 User Manual

Page 306

background image

Remote Control Operation

C5/K1/K3 Integrated Satellite Terminal System

B–22

Rev. 0

Outdoor Unit
Status

Command:
Response:

>add/OUS_'cr'

C-Band:
MOD_xxx'cr'
COM_xxx'cr'
SFLT_xx'cr''lf']

C-Band:
Module (OK/FLT)
Communication (OK/FLT)
Number of stored faults logged (0 to 10)

Raw BER

Command:
Response:

>add/RBER_xm.mE-ee'cr''lf']

Where:

x = < or > (data modifier to indicate that the error rate is
less than or greater than the returned value).

m.m = 1.0 to 9.9 (error rate mantissa).

ee = 1 to 99 (error rate exponent).

Notes:

1. The 'x' (< or >) parameter is only returned if the error

rate has exceeded the computational resolution of
the system.

2. 'No Data' is returned if the error rate cannot be

calculated.

3. 'Sampling' is returned if not enough data is currently

available to calculate the error rate.

Corrected
BER

Command:
Response:

>add/CBER_xm.mE-ee'cr''lf']

Where:

x = < or > (data modifier to indicate that the error rate is
less than or greater than the returned value).

m.m = 1.0 to 9.9 (error rate mantissa).

ee = 1 to 99 (error rate exponent).

Notes:

1. The 'x' (< or >) parameter is only returned if the error

rate has exceeded the computational resolution of
the system.

2. 'No Data' is returned if the error rate cannot be

calculated.

3. 'Sampling' is returned if not enough data is currently

available to calculate the error rate.

This manual is related to the following products: