C5/K1/K3 Integrated Satellite Terminal System

Specifications

Rev. 0

2–39

2.5.1.3

Transmit Clock Switching Due to Failure of Selected Clock

The terminal will automatically switch the transmit clock source to SCT internal on failure
of terminal timing.

2.5.1.4

Transmit Clock Phase Adjustment

The transmit clock phase can be set by the operator to NORMAL, INVERTED, or AUTO
mode.

2.5.1.5

Transmit Data Phase Adjustment

The transmit data phase can be set by the operator to NORMAL or INVERTED.

2.5.1.6

Doppler Buffer Clock Source

The Doppler/plesiochronous buffer clock can be selected by the operator from the
following sources:

Receive Clock
Transmit Terrestrial
Clock

Must be within

% 100 PPM of the nominal receive data rate. Or it can be

any multiple of 8 kHz as long as it is

# 64 kHz but " 4.376 MHz or any

multiple of 8 kHz or 600 Hz as long as it is

# 32 kHz and < 64 kHz, or

any multiple of 600 Hz as it is

# 2.4 kHz but " 32 kHz.

External Clock

Must be within

% 100 PPM of the nominal. Or it can be any multiple of

8 kHz as long as it is

# 32 kHz but " 4.376 MHz or any multiple of

600 Hz as long as it

# 2.4 kHz but " 32 kHz.

SCT (Internal)

% 0.01 PPM

2.5.1.7

Receive Clock Switching Due to Failure of Selected Clock

The terminal will automatically switch the receive clock source to receive satellite on
failure of the selected clock.