beautypg.com

Idu receive specification, 2 idu, Receive specification – Comtech EF Data C5 User Manual

Page 87

background image

C5/K1/K3 Integrated Satellite Terminal System

Specifications

Rev. 0

2–53

2.7.2.2 IDU

Receive Specification

Refer to Table 2-32 for IDU receive specifications.

Table 2-32. IDU Receive Specifications

Parameters

Specifications

IF Input Frequency Range

950 to 1450 MHz, in 100 Hz steps

IF Input Level
Desired Signal

-135 dBm +10 log (Symbol Rate) minimum
-85 dBm +10 log (Symbol Rate) maximum

IF Input Composite Power:
Symbol Rate

> = 64 ks/s
< = 64 ks/s

Absolute Maximum

+40 dBc with respect to RX signal
+50 dBc with respect to RX signal
-5 dBm

IF Input Impedance

50

! % 10%

IF Input Return Loss
(950 to 1700 MHz)

> = 10 dB at 50

!

RX-AUX Output

Nominal 0 dB gain from IF Input

% 3 dB

Baseband Filtering

EFData Closed, Comstream Closed, Fairchild Closed

Demodulation

Coherent QPSK or BPSK

Acquisition Range

0 kHz to 70 kHz, programmable in 100 Hz increments, range is
rounded to nearest multiple of the opening symbol rate

Symbol Rate Range (variable)

4.8 to 2500 ks/s

Data Rate Range (variable)

QPSK
BPSK

4.8 to 4375 kbit/s, in 1.0 bit/s steps
2.4 to 1250 kbit/s, in 1 bit/s steps

Forward Error Correction

Viterbi K = 7, 1/2, 3/4, 7/8 rate
Optional: Sequential K = 36, 1/2, 3/4, 7/8 rate
Optional: Reed-Solomon IESS 308/309 Concatenated 225.205 T = 10

Bit Error Rate:

Viterbi 1/2 Rate
Viterbi 1/2 Rate (with Reed-
Solomon)

1 x 10

-8

for Eb/N0 7.2 dB

1 x 10

-10

for Eb/N0 5.0 dB

Ambiguity Resolution Method

Differential Decoder

Descrambling

CCITT V.35 IESS modified, CCITT V.35 (EFD or CSC Closed), FDC,
2

15

-1 SYNC

This manual is related to the following products: