beautypg.com

Comtech EF Data C5 User Manual

Page 318

background image

Remote Control Operation

C5/K1/K3 Integrated Satellite Terminal System

B–34

Rev. 0

Bulk
Consol.
Status
(continued)

Parameter

Number

Parameter Name
(Command Reference)

Description

104

105

106

107

108

109

Reserved null field.

Transmit BPSK Data Ordering
(ref. 'TDA_' command).

Receive BPSK Data Ordering
(ref. 'RDA_' command).

RTS TX-IF Control Mode
(ref. 'RTSM_' command).

CTS Delay Time
(ref. 'CTSD_' command).

Carrier Only Mode
(ref. 'COM_' command).

p105 = n, where 'n' is '0' (NRM) or '1' (INV).

p106 = n, where 'n' is '0' (NRM) or '1' (INV).

p107 = n, where ,n, is '0' (OFF) or '1' (ON).

p108 = nn, CTS delay time in seconds.

p109 = n, where 'n' is '0' (OFF),'1' (CENTER-CW), '2'
(DUAL-CW), '3' (OFFSET-CW).

Notes:

1.

Data will only be returned if TX Overhead is programmed for ASYNC. Comma is always returned.

2.

Data will only be returned if RX Overhead is programmed for ASYNC. Comma is always returned.

This manual is related to the following products: