Interface, B.3.3 interface – Comtech EF Data C5 User Manual
Page 293
![background image](https://www.manualsdir.com/files/778813/content/doc293.png)
C5/K1/K3 Integrated Satellite Terminal System
Remote Control Operation
Rev. 0
B–9
B.3.3 Interface
Interface
Transmit
Overhead Type
Command:
Response:
Status:
Response:
Where: xxxxx = NONE, EFD, or ASYNC.
Interface
Receive
Overhead Type
Command:
Response:
Status:
Response:
Where: xxxxx = NONE, EFD, or ASYNC.
TX Driver Type
Command:
Response:
Status:
Response:
Where: xxxxx = G703, V35, RS422, or RS232.
RX Driver Type
Command:
Response:
Status:
Response:
Where: xxxxx = G703, V35, RS422, or RS232.
Transmit Clock
Command:
Response:
Status:
Response:
Where: xxx = INT (internal SCT clock), EXT
(external TX terrestrial clock), REF (external clock-
reference frequency).
External Clock-
Reference
Frequency
Command:
Response:
Status:
Response:
Where: nnnnn.n = 8.0 to 10000.0 (external clock
frequency in kHz).
Transmit Clock
Phase
Command:
Response:
Status:
Response:
Where: xxxx = NRM (normal clock phasing), INV
(inverted clock phasing), AUTO (automatic clock
phasing).
Buffer Clock
Command:
Response:
Status:
Response:
Where: xxx = INT (internal SCT clock), EXT
(external TX terrestrial clock), SAT (receive satellite
clock), REF (external clock-reference frequency),
Receive Clock
Phase
Command:
Response:
Status:
Response:
Where: xxx = NRM (normal clock phasing), INV
(inverted clock phasing).
Base Band Loop
Back
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.