beautypg.com

Comtech EF Data C5 User Manual

Page 313

background image

C5/K1/K3 Integrated Satellite Terminal System

Remote Control Operation

Rev. 0

B–29

Bulk
Consol.
Status
(continued)

Parameter

Number

Parameter Name
(Command Reference)

Description

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

Demodulator IF frequency
(ref. 'DF_' command).

Demodulator rate
(ref. 'DR_' command).

Demodulator preset A assignment
(ref. 'ADRA_' command).

Demodulator preset B assignment
(ref. 'ADRB_' command).

Demodulator preset C assignment
(ref. 'ADRC_' command).

Demodulator preset D assignment
(ref. 'ADRD_' command).

Demodulator preset V assignment
(ref. 'ADRV_' command).

Descrambler enable
(ref. 'DE_' command).

Differential decoder enable
(ref. 'DDEC_' command).

Reserved null field.
Demodulator Band
(ref. 'DB_' command)

RF Loopback
(ref. 'RFL_' command).

IF Loopback
(ref. 'IFL_' command).

Sweep Center frequency
(ref. 'SCF_' command).

Sweep width range
(ref. 'SWR_' command).

Sweep reacquisition
(ref. 'SR_' command).

BER threshold
(ref. 'BERT_' command).

Demodulator type
(ref. 'DT_' command).

Demodulator decoder type
(ref. 'DDT_' command).

C-Band:
p15 = n.nnnnnnn, demodulator IF frequency in GHz.
Ku-Band:
p15 = nn.nnnnnnn, demodulator IF frequency in GHz.

p16 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p17 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p18 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p19 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p20 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p21 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p22 = n, where 'n' is '0' (off) or (on).

p23 = n, where 'n' is '0' (off) or (on).

Ku-Band:
p24 = n, where 'n' is 'A', 'B,' or 'C' (RX Frequency band).

p25 = n, where 'n' is '0' (off) or '1' (on).

p26 = n, where 'n' is '0' (off) or '1' (on).

p27 = snnnnn, sweep center frequency in Hertz.

p28 = nnnnn, sweep range in Hertz.

p29 = nnn, reacquisition time in seconds.

p30 = xxxx, BER threshold.

p31 = n, where 'n' is '0' (EFD), '1' (INTL), '3' (FDC), or '4'
(CSC).

p32 = n, where 'n' is '0' (SEQ) or '1' (VIT).

This manual is related to the following products: