beautypg.com

Table 3-7 – Comtech EF Data C5 User Manual

Page 119

background image

C5/K1/K3 Integrated Satellite Terminal System

Installation

Rev. 0

3–23

Table 3-7. 34-Pin Winchester Connector Pinouts (V.35)

34

V.35

34

V.35

R

RX Data A (RD A)

C

Request to Send (RTS)

T

RX Data B (RD B)

D

Clear to Send (CTS)

P

Send Data A (SD A)

F

RX Line Signal Detect (RLSD)

S

Send Data B (SD B)

E

Data Set Ready (DSR)

Y

Serial Clock TX A (SCT A)

c (CC)

External Reference Clock A (EXC A)

a (AA)

Serial Clock TX B (SCT B)

d (DD)

External Reference Clock B (EXC B)

U

Serial Clock TX External A (SCTE A)

n (NN)

Demodulator Fault

W

Serial Clock TX External B (SCTE B)

m (MM)

Modulator Fault

V

Serial Clock RX A (SCR A)

A

Ground

X

Serial Clock RX B (SCR B)

B

Ground

Note: Pins H, J, K, L, M, N, Z, b (BB), e (EE), f (FF), h (HH), j (JJ), k (KK), l (LL) have no
connection.

The IDU is available with a Winchester

% V.35 as the data I/O connector (PL/6032).

There is a jumper on the unit that either opens or closes the CC line.

The interface is

shipped with jumpers in positions 2 and 3, because:

1. EFData has determined that several locations use Fireberd% test equipment and a

conflict will occur if CC is connected between the modem and the Fireberd%.

2. Placing the jumper in positions 2 and 3 opens up the CC line, because the

TTC/Fireberd% test equipment interfaces use the line for DTE/DCE control.

3. Grounding pin CC at the Fireberd% interface will change the Fireberd % to a

DCE device.

4. EFData uses the CC and DD for the input master clock (same as the external clock

input to the modem). To input an external clock, change the jumper to positions 1
and 2 (the pin closest to the Winchester connector).

This manual is related to the following products: