beautypg.com

Receive interface faults, Common equipment faults, Outdoor unit – Comtech EF Data C5 User Manual

Page 162: 4 receive interface faults, 5 common equipment faults, 6 outdoor unit

background image

Operation

C5/K1/K3 Integrated Satellite Terminal System

4–36

Rev. 0

4.1.3.8.4 Receive

Interface

Faults

BUFFER UNDERFLOW

Buffer underflow alarm. Indicates that a buffer underflow has
occurred.

BUFFER OVERFLOW

Buffer overflow alarm. Indicates that a buffer overflow has
occurred.

RX DATA/AIS

Data or AIS. When data fault is selected in the Configuration
Interface menu (Figure 4-6), the fault indicates a data stable
condition. This indicates the data coming from the satellite is
all 1s or 0s (i.e., data is not transitioning). When AIS is
selected, the Alarm indicates the data is all 1s from the
satellite. When None is selected in the Configuration Interface
menu, the RX Data/AIS Fault/Alarm is not activated.

Note: AIS is an alarm, not a switching fault.

FRAME BER

Frame BER fault. Indicates that the frame BER exceeds 1

-3

.

BUFFER CLK PLL

Buffer clock phase-locked loop fault. Indicates the buffer
clock PLL is not locked.

BUFFER CLK ACT

Activity detector alarm of the selected interface receive clock.
The interface will fall back to the satellite clock when this
fault is active.

DEMUX LOCK

DEMUX lock fault. Indicates that the DEMUX is not locked.

RX 2047 LOCK

RX 2047 lock alarm. Indicates the RX 2047 data pattern is not
locked.

Note: This alarm is only active if RX 2047 is ON.

BUFFER FULL

Buffer full alarm. Indicates the buffer is less than 10% or
greater than 90% full.

4.1.3.8.5 Common

Equipment

Faults

BATTERY/CLOCK

Battery or clock fault.

-12V SUPPLY

-12V power supply fault.

+12V SUPPLY

+12V power supply fault.

+5V SUPPLY

+5V power supply fault.

CONTROLLER

Controller fault. Typically indicates the controller has gone
through a power on/off cycle.

INTERFACE MODULE

Interface module fault. Typically indicates that the interface
module is missing or will not program.

SELF TEST

Built in self-test fault.

IDU POWER SUPPLY

IDU Power Supply fault. Typically indicates that the power
supply is missing or will not program.

4.1.3.8.6 Outdoor

Unit

MODULE

Module fault

COMMUNICATION

Communication alarm.

This manual is related to the following products: