Receive interface faults, Common equipment faults, Outdoor unit – Comtech EF Data C5 User Manual
Page 162: 4 receive interface faults, 5 common equipment faults, 6 outdoor unit
Operation
C5/K1/K3 Integrated Satellite Terminal System
4–36
Rev. 0
4.1.3.8.4 Receive
Interface
Faults
BUFFER UNDERFLOW
Buffer underflow alarm. Indicates that a buffer underflow has
occurred.
BUFFER OVERFLOW
Buffer overflow alarm. Indicates that a buffer overflow has
occurred.
RX DATA/AIS
Data or AIS. When data fault is selected in the Configuration
Interface menu (Figure 4-6), the fault indicates a data stable
condition. This indicates the data coming from the satellite is
all 1s or 0s (i.e., data is not transitioning). When AIS is
selected, the Alarm indicates the data is all 1s from the
satellite. When None is selected in the Configuration Interface
menu, the RX Data/AIS Fault/Alarm is not activated.
Note: AIS is an alarm, not a switching fault.
FRAME BER
Frame BER fault. Indicates that the frame BER exceeds 1
-3
.
BUFFER CLK PLL
Buffer clock phase-locked loop fault. Indicates the buffer
clock PLL is not locked.
BUFFER CLK ACT
Activity detector alarm of the selected interface receive clock.
The interface will fall back to the satellite clock when this
fault is active.
DEMUX LOCK
DEMUX lock fault. Indicates that the DEMUX is not locked.
RX 2047 LOCK
RX 2047 lock alarm. Indicates the RX 2047 data pattern is not
locked.
Note: This alarm is only active if RX 2047 is ON.
BUFFER FULL
Buffer full alarm. Indicates the buffer is less than 10% or
greater than 90% full.
4.1.3.8.5 Common
Equipment
Faults
BATTERY/CLOCK
Battery or clock fault.
-12V SUPPLY
-12V power supply fault.
+12V SUPPLY
+12V power supply fault.
+5V SUPPLY
+5V power supply fault.
CONTROLLER
Controller fault. Typically indicates the controller has gone
through a power on/off cycle.
INTERFACE MODULE
Interface module fault. Typically indicates that the interface
module is missing or will not program.
SELF TEST
Built in self-test fault.
IDU POWER SUPPLY
IDU Power Supply fault. Typically indicates that the power
supply is missing or will not program.
4.1.3.8.6 Outdoor
Unit
MODULE
Module fault
COMMUNICATION
Communication alarm.