Revision emulation operation, Clocking options, Eia-232, eia-422, or v.35 master/master – Comtech EF Data C5 User Manual
Page 197
C5/K1/K3 Integrated Satellite Terminal System
Operation
Rev. 0
4–71
Asynchronous Overhead with AUPC is a closed network application that gives the user
the ability to communicate from the hub site to the remote site through the added
overhead. The user can use the AUPC feature that remotely controls the remote modem’s
power level, according to parameters programmed by the user. The user can also
remotely monitor and control the remote modem by sending remote commands over the
link via the overhead. This can be accomplished by a local terminal or Monitor and
Control system.
Refer to Appendix A for more information on the Asynchronous interface with AUPC.
4.3 Revision
Emulation
Operation
To program an emulation mode from Version 1.1.1 through the current version, use the
revision emulation feature in the Utility Modem Type menu.
Refer to Table 4-4.
Table 4-4. SDT-5200 IDU Revision Emulation
Software Version #
Firmware #
Description of Change
1.1.1
FW/7414-1
Original release.
4.4 Clocking
Options
Clocking of the data from the terrestrial equipment to the satellite (and vice versa) will
depend on the application. This section describes the most common options and
recommended configurations.
4.4.1
EIA-232, EIA-422, or V.35 Master/Master
Refer to Figure 4-24 for:
! Clocking block diagram
! Transmit clock options
! Buffer clock options
! V.35 timing signals
! EIA-422 timing signals