Comtech EF Data C5 User Manual
Page 294
Remote Control Operation
C5/K1/K3 Integrated Satellite Terminal System
B–10
Rev. 0
Interface Loop-
back
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.
Interface Loop
Timing
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.
Interface Buffer
Size
Buffer size programming is supported in two
formats; bits, or milliseconds. The selected format
must be chosen using the buffer programming
command (IBP_). If the buffer is to be programmed
in milliseconds and plesiochronous slips are
required use the receive framing structure
command (IRFS_) to define the proper framing
format.
Note: For Drop & Insert: Only milliseconds format is
allowed.
Interface Buffer
Size (Bit Format)
Command:
Response:
Status:
Response:
Where: nnnnnn = 32 to 262144 in 16 bit
increments.
Interface Buffer
Size
(Millisecond
Format)
Command:
Response:
Status:
Response:
Where: nn = 0 to 99 (buffer size in milliseconds).
Interface Buffer
Center
Command:
Response:
Interface Buffer
Programming
Command:
Response:
Status:
Response:
Where: xxxx = BITS or MS (milliseconds).
Note: For Drop & Insert: Only milliseconds format is
allowed.
Interface
Receive Framing
Structure
Command:
Response:
Status:
Response:
Where:
ff = T1 or E1 (frame type).
ssss = NONE or G704 (framing structure).
Interface
Substitute
Pattern
(Transmit 2047
Pattern)
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.
Interface Read
Error Select
(Receive 2047
Pattern)
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.