Comtech EF Data C5 User Manual
Page 147

C5/K1/K3 Integrated Satellite Terminal System
Operation
Rev. 0
4–21
RX DATA FAULT
Receive data fault. Press [
$] or [%] to select one of the following
modes:
The data monitored for RX data is coming from the satellite. Refer to
TX DATA FAULT for a description of function choices.
Upon entry, the current RX data fault that is being monitored is
displayed. Press [
$] or [%] to make the selection. Press [ENTER] to
execute the change.
Note: This menu is only available when the overhead interface
PCB is installed.
TX 2047 PATTERN
(Test Mode Configuration)
Programs the transmitter to on or off to insert a 2047 pattern instead
of the normal transmit data.
Upon entry, the status is displayed. Press [
$] or [%] to make the
selection. Press [ENTER] to execute the change.
Note: This menu is only available when the overhead interface
PCB is installed.
RX 2047 PATTERN
(Test Mode Configuration)
Programs the modem to receive a 2047 pattern as the normal receive
data, and allows the BER monitor to work on that 2047 pattern.
Upon entry, the status is displayed. Press [
$] or [%] to select on or off.
Press [ENTER] to execute the change.
Note: This menu is only available when the overhead interface PCB
is installed.
TX CODING FORMAT
Programs the transmitter for AMI, B8ZS, or HDB3 coding of the
baseband data.
Upon entry, the current coding format is displayed. Press [
$] or [%] to
make the selection. Press [ENTER] to execute the change.
Note: This menu is only available when the TX G.703 interface is
programmed.
RX CODING FORMAT
Programs the receiver for AMI, B8ZS, or HDB3 coding.
Upon entry, the current coding format is displayed. Press [
$] or [%] to
make the selection. Press [ENTER] to execute the change.
Note: This menu is only available when the RX G.703 interface is
programmed.
ASYNC TX BAUD
Programs the ASYNC overhead TX baud rate for 110 to 38400 bit/s.
Upon entry, the status of the ASYNC TX baud rate is displayed.
Press [
$] or [%] to select on of the following baud rates (bit/s): 110,
150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400.
Press enter to execute the change.
Note: Only available for the ASYNC option.