Comtech EF Data C5 User Manual
Page 317
C5/K1/K3 Integrated Satellite Terminal System
Remote Control Operation
Rev. 0
B–33
Bulk
Consol.
Status
(continued)
Parameter
Number
Parameter Name
(Command Reference)
Description
(Note 1)
(Note 2)
(Note 1)
(Note 2)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 2)
(Note 2)
(Note 1)
(Note 1)
91
92
93
94
95
96
97
98
99
100
101
102
103
ASYNC TX Channel Parity
(ref. 'TOCP_' command).
ASYNC RX Channel Parity
(ref. 'ROCP_' command).
ASYNC TX Communications Type
(ref. 'TCT_' command).
ASYNC RX Communications Type
(ref. 'RCT_' command).
AUPC Local Power enable ON/OFF
(ref. 'LPC_' command).
AUPC Nominal Power Value
(ref. 'NOMP_' command).
AUPC Minimum Power Value
(ref. 'MINP_' command).
AUPC Maximum Power Value
(ref. 'MAXP_' command).
AUPC EBN0 Target Set Point
(ref. 'ENSP_' command).
AUPC Max. Tracking Rate
(ref. 'MAXT_' command).
AUPC Local Carrier Loss
(ref. 'LCL_' command).
AUPC Remote Carrier Loss
(ref. 'RCL_' command).
Reserved null field.
p91 = xxxx, where 'xxxx' is the currently programmed
parity.
p92 = xxxx, where 'xxxx' is the currently programmed
parity.
p93 = n, where 'n' is '0' (RS232), '1' (RS485_4WIRE), '2'
(RS485_2WIRE).
p94 = n, where 'n' is '0' (RS232), '1' (RS485).
p95 = n, where 'n' is '0' (off) or '1' (on).
p96 = snn.n, where 'snn.n' Nominal Power Value in dBm.
p97 = snn.n, where 'snn.n' Minimum Power Value in dBm.
p98 = snn.n, where 'snn.n' Maximum Power Value in dBm.
p99 = nn.n, where 'nn.n' EBN0 Target Set Point in dB.
p100 = n.n, where 'n.n' is the Max. Tracking Rate in
dB/Min.
p101 = n, where 'n' is '0' (HOLD), '1' (NOMINAL), or '2'
(MAXIMUM).
p102 = n, where 'n' is '0' (HOLD), '1' (NOMINAL), or '2'
(MAXIMUM).