beautypg.com

Comtech EF Data C5 User Manual

Page 312

background image

Remote Control Operation

C5/K1/K3 Integrated Satellite Terminal System

B–28

Rev. 0

Bulk
Consol.
Status

Command:
Response:

>add/BCS_p1,p2,p3, . . . pn'cr''lf']

This command causes bulk modem status to be returned.
To reduce the length of the response, message parameter
data are returned without identifiers. However, parameter
identification can be determined by order of return. Each
status parameter is terminated with a ',' (comma) except for
the last parameter which has the standard message
termination sequence ('cr''lf']). Most of the data returned is
formatted the same way as the single command status
request (refer to the appropriate portions of this document
in preceding sections). Additional configuration status of
new options and features will always be appended to the
end.

Where 'pn' is the last parameter returned.

Parameter

Number

Parameter Name
(Command Reference)

Description

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Modulator RF output
(ref. 'RF_' command).

Modulator IF frequency
(ref. 'MF_' command).

Modulator rate
(ref. 'MR_' command).

Modulator preset 'A' assignment
(ref. 'AMRA_' command).

Modulator preset 'B' assignment
(ref. 'AMRB_' command).

Modulator preset 'C' assignment
(ref. 'AMRC_' command).

Modulator preset 'D' assignment
(ref. 'AMRD_' command).

Modulator preset 'V' assignment
(ref. 'AMRV_' command).

Modulator output power level
(ref. 'MOP_' command).

Scrambler enable
(ref. 'SE_' command).

Differential encoder enable
(ref. 'DENC_' command).

Modulator type
(ref. 'MT_' command).

Modulator encoder type
(ref. 'MET_' command).

Carrier only mode ON/OFF.

p1 = n, where 'n' is '0' (off) or '1' (on).

C-Band:
p2 = n.nnnnnnn, IF frequency in GHz.
Ku-Band:
p2 = nn.nnnnnnn, IF frequency in GHz.

p3 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p4 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p5 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p6 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p7 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p8 = nnnn_mmmm.mmm, code rate/data rate in Kbps.

p9 = snn.n, transmitter output power level in dBm.

p10 = n, where 'n' is '0' (off) or '1' (on).

p11 = n, where 'n' is '0' (off) or '1' (on).

p12 = n, where 'n' is '0' (EFD), '1' (INTL), '3' (FDC),'4'
(CSC), or '6' (SDM51).

p13 = n, where 'n' is '0' (SEQ), '1' (VIT).

p14 = n, where 'n' is '0' (off) or '1' (on).

This manual is related to the following products: