Initial defaults, 6 initial defaults – Comtech EF Data C5 User Manual
Page 207
C5/K1/K3 Integrated Satellite Terminal System
Operation
Rev. 0
4–81
4.6 Initial
Defaults
Initial default settings for the Satellite Terminal System are listed in Table 4-5.
Table 4-5. Initial Defaults
Function
C5
K1
K3
C5 ASYNC
Modulator Configuration
TX DATA RATE (kbit/s)
64
64
64
64
CODE RATE
1/2
1/2
1/2
1/2
MODULATION
QPSK
QPSK
QPSK
QPSK
TX IF FREQ (GHz)
6.425
14.500
14.500
6.425
RF OUTPUT
OFF
OFF
OFF
OFF
TX POWER (dBm)
+32.0
+24.0
+29.0
+32.0
SCRAMBLER
ON
ON
ON
ON
DIFF ENCODER
ON
ON
ON
ON
CARRIER MODE
Normal
Normal
Normal
Normal
REED-SOLOMON ENCODER
Note 1
Note 1
Note 1
Note 1
Demodulator Configuration
RX DATA RATE
64
64
64
64
CODE RATE
1/2
1/2
1/2
1/2
DEMODULATION
QPSK
QPSK
QPSK
QPSK
RX IF FREQ (GHz)
4.200
12.200
11.700
4.200
DESCRAMBLER
ON
ON
ON
ON
DIFF DECODER
ON
ON
ON
ON
RF LOOP
OFF
OFF
OFF
OFF
IF LOOP
OFF
OFF
OFF
OFF
BER THRESHOLD
NONE
NONE
NONE
NONE
SWEEP CENTER
0 Hz
0 Hz
0 Hz
0 Hz
SWEEP RANGE
70k
70k
70k
70k
REACQUISITION
0 SEC
0 SEC
0 SEC
0 SEC
REED-SOL DECODER
Note 1
Note 1
Note 1
Note 1
Interface Configuration
TX CLK SOURCE
SCT(INT)
SCT(INT)
SCT(INT)
SCT(INT)
TX CLK PHASE
AUTO
AUTO
AUTO
AUTO
EXT-REF FREQ
1544K
1544K
1544K
1544K
BUFFER CLK
RX (SAT)
RX (SAT)
RX (SAT)
RX (SAT)
RX CLK PHASE
NORM
NORM
NORM
NORM
BASEBAND LOOP
Off
Off
Off
Off
INTERFACE LOOP
Off (Note 2)
Off (Note 2)
Off (Note 2)
Off (Note 2)
BUFFER SIZE
384
384
384
384
LOOP TIMING
Off
Off
Off
Off
TX DATA FAULT
Note 2
Note 2
Note 2
Off
RX DATA FAULT
Note 2
Note 2
Note 2
Off
TX 2047
Note 2
Note 2
Note 2
Off
RX 2047
Note 2
Note 2
Note 2
Off
ASYNC TX BAUD
Note 3
Note 3
Note 3
1200
ASYNC RX BAUD
Note 3
Note 3
Note 3
1200
ASYNC TX LENGTH
Note 3
Note 3
Note 3
7
ASYNC RX LENGTH
Note 3
Note 3
Note 3
7