External idu connections, 4 external idu connections – Comtech EF Data C5 User Manual
Page 111
C5/K1/K3 Integrated Satellite Terminal System
Installation
Rev. 0
3–15
3.4
External IDU Connections
When a breakout panel, such as the UB-300, is not required, the rear panel connectors
provide all necessary external connections between the modem and other equipment.
Table 3-1 lists these connectors.
Note: Refer to the EFData UB-300 Universal Breakout Panel Installation and Operation
Manual for connecting the UB-300 breakout panel.
Table 3-1. Modem Rear Panel Connectors
Name
Ref. Desig.
Connector Type
Function
REMOTE
J6
9-pin D
Remote Interface
FAULT
J7
9-pin D
FORM C Fault Relay Contacts
DATA I/O
J8
25-pin D
34-pin
37-pin D
50-pin D
Data Input/Output (standard modem)
V.35
EIA-422
Overhead Interface
See Figure 3-6 through Figure 3-9.
AUX 1
J9
9-pin D
(TTL) Faults
Satellite Clock
Demod I/Q
Automatic Gain Control (AGC) Out
ALARMS
J10
9-pin D
FORM C Alarm
Relay Contacts
RX/IF OUTPUT
CP1
BNC
RF Output. Monitor
RX/IF INPUT
CP2
TNC
L-Band input.
TX/IF OUTPUT
CP3
Type N
RF Output (+36 VDC)
AC INPUT
NONE
IEC
GROUND
NONE
10-32 Stud
Note: The European EMC Directive (EN55022, EN50082-1) requires using properly shielded
cables for DATA I/O. These cables shall be double-shielded from end-to-end, ensuring a
continuous ground shield.