Unpacking, Installation, A.3.1.6 unpacking – Comtech EF Data C5 User Manual
Page 282: A.3.1.7 installation
Options
C5/K1/K3 Integrated Satellite Terminal System
A–38
Rev. 0
A.3.1.6 Unpacking
CAUTION
This equipment contains parts and assemblies sensitive to damage by ESD.
Use ESD precautionary procedures when touching, removing, or inserting
PCBs.
1. Remove the Reed-Solomon PCB and mounting hardware from the cardboard
caddypack and anti-static material.
2. Check the packing list to ensure the shipment is complete.
3. Inspect the Reed-Solomon PCB for any shipping damage.
A.3.1.7 Installation
The following tool is required to install the overhead interface PCB:
Description
Application
Phillips
+ Screwdriver
To remove and replace cross-point screws.
Use the following information to install the Reed-Solomon Codec PCB as a daughter
card on the main PCB.
Refer to Figure A-13 for installation location of the Reed-Solomon daughter card.
CAUTION
Turn the power off before installation. High current VDC is present. Failure
to do so could result in damage to modem components.
1. Turn off the modem and unplug the power supply.
2. Remove the rear panel retaining screws. Using the finger pulls, slide the main
modem assembly out from the rear of the modem chassis.
3. Install the Reed-Solomon PCB to the main PCB by mating the male simm
connectors with the female simm connectors in the position shown in
Figure A-13.
4. After completing the above installation procedure, turn on the modem. If the
Reed-Solomon PCB was installed properly, the Utility Interface/Interface
Module menu will display “OPT:Reed-Solomon” Refer to Chapter 4 for more
information.