beautypg.com

Remote control, Monitored signals – Comtech EF Data C5 User Manual

Page 286

background image

Remote Control Operation

C5/K1/K3 Integrated Satellite Terminal System

B–2

Rev. 0

Messages on the remote link fall into the categories of commands and responses.

Commands are messages, which are transmitted to a satellite modem, while responses are
messages returned by a satellite modem in response to a command.

The general message structure is as follows:

! Start Character

! Device Address
! Command/Response

! End of Message Character

B.2.1 Remote

Control

All terminal functions can be controlled remotely through the Remote connector on the
rear panel.

Interface Types:

! EIA-485 (2- or 4-Wire)

! EIA-232

! Baud Rate Range (150 to 19.2 kbit/s)

! ASCII Characters

! 11 bits per character:

B.2.2 Monitored

Signals

The operator can display/read one of the following, continually-updated performance
monitors:

! Receive signal level -15 to -85 dBm, " 5 dB for Symbol Rates > 190 ks/s

-25 to -100 dBm,

" 5 dB for Symbol Rates # 190 ks/s

! Raw BER

! Corrected BER

! Eb/N0, 0.1 dB resolution

! Receive frequency offset, 1 Hz resolution

! Sweep frequency

! Buffer fill status