All terminal functions are controlled remotely through the remote connector on the rear
panel. Refer to Appendix B for the Remote Control Specification. Refer to Table 2-28 for
functions controlled.
Table 2-28. Remote Control Functions
Transmit
Digital Data Rate
2.4 kbit/s to 4.375 Mbit/s, in 1 bit steps
Code Rate
BPSK 1/2
QPSK 1/2, 3/4, and 7/8
Encoder Type
Viterbi
Sequential
Reed-Solomon Encoder
On or Off
Transmit Frequency
C-Band: 5.925 to 6.425 GHz, in 100 Hz steps
Ku-Band: 14.0 to 14.5 GHz, in 100 Hz steps
Transmit RF
On or Off
Transmit Modulation Type
EFD, CSC, FDC, and all closed networks
Transmit Power
C-Band: +25 to +38 dBm, in 0.1 dB steps
Ku-Band K1: +17 to +30 dBm, in 0.1 dB steps
Ku-Band K3: +22 to +35 dBm, in 0.1 dB steps
Scrambler Enable
On or Off
Differential Encoder
On or Off
Transmit Spectrum Rotation
Normal or Inverted
Transmit BPSK Bit Order
Normal or Inverted
Carrier Only Mode
Normal, Dual, Offset, or Center
Receive
Digital Data Rate
2.4 to 4375 kbit/s, in 1 bit steps
Code Rate
BPSK 1/2
QPSK 1/2, 3/4, and 7/8
Decoder Type
Viterbi or Sequential
Reed-Solomon Decoder
On or Off
Receive Frequency
C-Band:
3.7 to 4.2 GHz
Ku-Band:
10.95 to 11.45 GHz, in 100 Hz steps
11.2 to 11.7 GHz, in 100 Hz steps
11.7 to 12.2 GHz, in 100 Hz steps
12.25 to 12.75 GHz, in 100 Hz steps
Receive Modulation Type
EFD, CSC, FDC, and all closed networks
Descrambler Enable
On or Off
Differential Decoder
On or Off
Receive Spectrum Rotation
Normal or Inverted
Receive BPSK Bit Order
Normal or Inverted
IF Loopback
On or Off
Sweep Center
-35 kHz to +35 kHz, in 1 Hz steps
Sweep Width
0 to 70 kHz, in 1 Hz steps
Sweep Reacquisition
0 to 999 seconds
BERT Threshold
10
-3
to 10
-8
or Off
Interface
Transmit OH Type
ASYNC or None
Receive OH Type
ASYNC or None
Transmit Driver Type
V.35, EIA-422, or EIA-232