C5/K1/K3 Integrated Satellite Terminal System

Remote Control Operation

Rev. 0

B–27

Bulk
Consol.
Analog
Status

Command:
Response:

>add/BCAS_p1,p2,p3, . . . pn'cr''lf']

This command is similar to the 'BCS_' command but,
returns MODEM analog parameters. Additional status of
new options and features will always be appended to the
end.

Where 'pn' is the last parameter returned.

Parameter

Number

Parameter Name
(Command Reference)

Description

1

2

3

4

5

6

Receive Signal Level
(ref. 'RSL_' command).

Raw BER
(ref. 'RBER_' command).

Corrected BER
(ref. 'CBER_' command).

Interface Read Error Status
(ref. 'IRES_' command).

EB/N0
(ref. 'EBN0_' command).

Buffer Fill Status
(ref. 'IBFS_' command).

p1 = xsnn.n, receive signal level in dBm.

p2 = xm.mE-ee.

p3 = xm.mE-ee.

p4 = tttt_xm.mE-ee.

p5 = xnn.n, EB/N0 in dB.

p6 = nn%, buffer fill status.

Note: Parameters 2 through 6 are dependent on carrier acquisition, if the decoder is not locked empty data blocks are returned
(,,,,,).