A.2.1.2 Remote

AUPC

This feature allows the user to monitor and control a remote modem location using the
front panel or serial port of the local modem. The operator can set or reset the following
commands:

! Baseband loopback

! TX 2047 pattern

! AUPC enable

The user can remotely monitor the receive 2047 BER. Refer to Appendix B for a
description of remote operation.

A.2.1.3

Theory of Operation

A.2.1.3.1

Terrestrial Data Interfaces

Two I/O interfaces are provided for the terrestrial data source: EIA-422 and V.35. The
operator must select the terrestrial interface type from the front panel under the Utility
Interface menu. Once selected, I/O data is routed to and from the appropriate drivers and
receivers.

A.2.1.3.2 ASYNC

Data

Interfaces

The EIA-485 and EIA-232 I/O interfaces are provided for the ASYNC data source. The
operator must select the ASYNC data interface type from the front panel under the Utility
Interface menu. Once selected, the I/O data is routed to and from the appropriate drivers
and receivers.