2.4 Acquisition
Times
Refer to Table 2-22 for acquisition times.
Table 2-22. Acquisition Times
Viterbi
6 dB Eb/N0 with
35 kHz frequency Uncertainty
Code Rate
Data Rate
Tacq
P (t < Tacq)
1/2
< 9.6 kbit/s
< 10 sec
95%
1/2
# 9.6 < 64 kbit/s
< 5 sec
95%
1/2
# 64 < 196 kbit/s
< 1 sec
95%
1/2
# 196 < 512 kbit/s
< 10 sec
95%
1/2
# 512 < 1000 kbit/s
< 2.5 sec
95%
1/2
# 1 < 2.5 Mbit/s
< 1 sec
95%
Sequential
6 dB Eb/N0 with
35 kHz frequency Uncertainty
Code Rate
Data Rate
Tacq
P (t < Tacq)
1/2
2.4 < 4.8 kbit/s
< 20 sec
95%
1/2
# 4.8 < 9.6 kbit/s
< 10 sec
95%
1/2
# 9.6 < 64 kbit/s
< 5 sec
95%
1/2
# 64 < 196 kbit/s
< 1 sec
95%
1/2
# 196 < 512 kbit/s
< 17 sec
95%
1/2
# 512 < 1000 kbit/s
< 2.5 sec
95%
1/2
# 1 < 2.5 Mbit/s
<1 sec
95%
2.4.1
Receive IF Carrier Acquisition Range
The terminal will automatically lock to a correctly formatted carrier, which is within
35 kHz of the display receive frequency.
2.4.2
AGC Output (IDU)
A programmable DC output, proportional to the IDU receive signal level is located at the
rear of the panel at 10 mA maximum, 0 to 10V. Default levels are 0v for minimum signal
condition, and 10V for maximum signal condition. The low level can be programmable
from 10 to 0V in 0.1V increments.