Rockwell Automation 57C650 AutoMax Programming Executive Version 3.8 User Manual
Page 262
KĆ2
AutoMax Programming Executive Version 3.x
DCS Drive Controller (M/N 57406) Example
The registers listed below are used to configure the DCS Drive Controller.
Current Version
AutoMax V2
Executive AutoMax
RegisterBit
RegisterBit
Function
1
4096
Analog Reference Input
2
4097
Analog Tach Feedback
3
4098
Armature Voltage Feedback
4
4099
Major Loop Current FDBK
5
4100
AC Line Voltage FDBK
41
4136
Tach Loss Delta Threshold
42
4137
PLL Max. Phase Change
43
4138
PLL Max. Period Change
51
0
4146
0
Fast Bridge Change Enable
Note that the register numbers used in the current version correspond to the old
register numbers plus 4095. Before executing the Import procedure, edit your
AutoMax V2 configuration task to set the register numbers for this module to their