Rockwell Automation 57C650 AutoMax Programming Executive Version 3.8 User Manual
Page 180
14Ć6
AutoMax Programming Executive Version 3.x
the rack configuration and the tasks only if they were designated as
reconstructible. If the rack configuration was not designated as
reconstructible, it cannot be recovered. Also, only reconstructible
tasks will be saved back to the personal computer.
Step 1.
Start at the DOS prompt in the root directory. Use the DOS
MAKE DIRECTORY command to create a system and rack
subdirectory, e.g.,
Step 2.
Access the AutoMax Programming Executive.
Step 3.
Go online and then access the Transfer menu.
Step 4.
Select Path from the Transfer menu. Change the path to
the system\rack subdirectory you created in step 1.
Step 5.
Select Save from the Transfer menu. Use the Save All
option described in 14.4.1 to save the rack configuration
and all the reconstructible tasks to the system\rack
subdirectory you created in step 1.
Step 6.
Return to the System Configurator. Use the Remove
command to delete the AutoMax rack you are recovering.
You will reĆcreate the rack in the next step.
Step 7.
Use the Import Rack procedure described in section
5.3.9.6 to reĆcreate the rack. When you are prompted for
the source directory path, enter the system\rack path you
created in step 1.