Rockwell Automation 825-P Modular Protection System for Motors User Manual User Manual
Page 204

204
Rockwell Automation Publication 825-UM004D-EN-P - April 2012
Chapter B Parameter List
Current Imb
Set
161
40062
400062
CI TRIP ENABLE
0 = N
0
—
—
Get/Set
1 = Y
162
40063
400063
CI TRIP LEVEL
5
80
15
1
%
Get/Set
163
40064
400064
CI TRIP DELAY
0
240
5
1
s
Get/Set
164
40065
400065
CI WARN ENABLE
0 = N
0
—
—
Get/Set
1 = Y
165
40066
400066
CI WARN LEVEL
5
80
10
1
%
Get/Set
166
40067
400067
CI WARN DELAY
0
240
10
1
s
Get/Set
Prot.
Disable
167
40068
400068
PROT INHIBT TIME
0 = Off
240
0
1
s
Get/Set
168
40069
400069
OL INHIBIT TIME
0 = Off
240
0
1
s
Get/Set
Start
Monitoring
169
40070
400070
START MOTOR TIME
0 = Off
240
0
1
s
Get/Set
Star Delta
Set
170
40071
400071
STAR-DELTA ENABL
0 = N
0
—
—
Get/Set
1 = Y
171
40072
400072
MAX STAR TIME
0 = Off
600
0
1
s
Get/Set
Start Inhbt
172
40073
400073
STARTS/HR
0 = Off
15
0
1
—
Get/Set
173
40074
400074
MIN. OFF TIME
0 = Off
150
0
1
min
Get/Set
Antibackspin
174
40075
400075
RESTART BLK TIME
0 = Off
60
0
1
min
Get/Set
Phase Rev
Set
175
40076
400076
PH REV. ENABLE
0 = N
0
—
—
Get/Set
1 = Y
Speed Sw
Set
176
40077
400077
SS TRIP DELAY
0 = Off
240
0
1
s
Get/Set
177
40078
400078
SS WARN DELAY
0 = Off
240
0
1
s
Get/Set
PTC Settings
178
40079
400079
PTC ENABLE
0 = N
0
—
—
Get/Set
1 = Y
179
40080
400080
PTC RESET MODE
0 = Manual
0
—
—
Get/Set
1 = Auto
RTD
Settings
180
40081
400081
RTD ENABLE
0 = N
0
—
—
Get/Set
1 = Y
181
40082
400082
RTD RESET MODE
0 = Manual
0
—
—
Get/Set
1 = Auto
182
40083
400083
RTD1 LOCATION
0 = Off
1 = Wdg
2 = Brg
3 = Amb
4 = Oth
0
—
—
Get/Set
183
40084
400084
RTD1 TYPE
0 = Pt100
1 = Ni100
2 = Ni120
3 = Cu10
0
—
—
Get/Set
184
40085
400085
RTD1 TRIP LEVEL
0 = Off
250
0
1
°C
Get/Set
185
40086
400086
RTD1 WARN LEVEL
0 = Off
250
0
1
°C
Get/Set
Group
DeviceNet
Param No.
Modbus Register
Parameter Name
Min
Max
Default
Scale
Factor
Units
Access
Read (0x03h)