Features

The 825-P DeviceNet Communication Card features the following:

The card receives the required power from the DeviceNet network.

Rotary switches let you set the node address and network data rate prior to
mounting in the 825-P Modular Protection System and applying power.
Alternatively, the switches can be set to positions that allow for
configuration of these settings over the DeviceNet network, utilizing a
network configuration tool such as RSNetWorx for DeviceNet.

Status indicators report the status of the device bus and network
communications. They are visible from the back panel of the 825-P
Modular Protection System as installed.

UCMM (Unconnected Message Manager) messages are supported with
the ability to allocate up to 3 explicit message connections concurrently.

DeviceNet Group 2 slave functionality including:

Explicit connection

Polled connection

1 COS (Change of State)/Cyclic connection

Full DeviceNet Parameter Object support allows EDS files to be extracted
from all units.

Settings are provided for user-defined behavior of the 825-P Modular
Protection System auxiliary relays for Comm Fault and Comm Idle
conditions.

Group 4 faulted node recovery is supported. You can configure a device
even when it is faulted on the network if the configuration tool supports
faulted node recovery.

DeviceLogix component technology provides the capability to perform
logic operations at the device level. A total of 80 function blocks are
supported.