A- specifications, Electrical ratings, Main circuits – Rockwell Automation 825-P Modular Protection System for Motors User Manual User Manual

Page 187: 400 v ac, 240v ac, 5 kv, 50/60 hz ± 3 hz, 67…300v ac (line-to-line), 80…1.1 ue, 300v ac

background image

Rockwell Automation Publication 825-UM004D-EN-P - November 2012

187

Appendix

A

Specifications

Electrical Ratings

Main Circuits

825 Converter Module

MCM2

MCM5

MCM20

MCM180

MCM420

MCM630N

825-MCM Converter Modules

Rated Operating Voltage U

e

400 V AC

240V AC

690V AC
600V AC

1,000V AC

600V AC

IEC:

CSA/UL:

Rated Impulse Strength U

imp

2.5 kV

6 kV

8 kV

Operating Current Range (A)

0.5-2.5

1-5

2.5-20

20-180

160-420

160-630

Rated Continuous Thermal Current
(A)

3

6

24

216

504

756

Rated Saturation Current

30

60

240

1350

3400

4600

Rated Frequency

50/60 Hz ± 3 Hz

Voltage Input Option Card

Rated Operating Voltage U

e

67…300V AC (line-to-line)

Operating Range

0.80…1.1 U

e

Rated Continuous Voltage

300V AC

Rated Insulation Voltage U

i

300V AC

Rated Impulse Strength U

imp

4 kV

Rated Frequency

50/60 Hz ± 5 Hz

Transition Voltage

5…15V

20…79V

PTC Thermistor Input

Type of Control Unit

Mark A

Max. No. of Sensors in Series

6

Max. Cold Resistance of PTC Sensor
Chain

1500

Ω

Trip Resistance

3400

Ω

± 150

Ω

Reset Resistance

1500

Ω

…1650

Ω

Short Circuit Trip Resistance

25

Ω

±

10