Troubleshooting and fault elimination, System error messages general error messages – Lenze EVS9332xP User Manual
Page 399

Troubleshooting and fault elimination
System error messages
General error messages
9.3
9.3.1
l
9.3−7
EDSVS9332P EN 5.0−07/2013
Remedy
Cause
Description
Fault message
Remedy
Cause
Description
Display
No.
x166
P16
Faulty transfer of system bus
(CAN) sync telegram.
The sync telegram from the
master (PLC) is out of sync cycle.
l
Set the "sync cycle" to the
transmission cycle of the
master (PLC) under C1121.
l
Note:
– C0362 displays the time
interval between 2 sync
telegrams.
– C0362 = 0: communication
interrupted.
The sync telegram of the master
(PLC) is not received.
l
Check communication channel.
l
Check baud rate, controller
address.
l
Note:
– C0362 displays the time
interval between 2 sync
telegrams.
– C0362 = 0: communication
interrupted.
The controller is enabled too fast.
Delay the controller enable.
The time delay required depends
on the time interval between the
sync telegrams.
x167
P17
Error "touch probe control".
Various function blocks use the
touch probe input at the same
time (e.g. FB DFSET and POS). A
conflict arises.
l
Configure another touch probe
input for FB POS (not possible
for FB DFSET).
l
Switch off monitoring
(C1289/1).
x168
P18
Internal limitation.
Arithmetic operation generated
data cannot be varied arbitrarily.
Wrongly specified values were
automatically limited internally.
C1298 = 1:
The negative position limit in
C1223 is outside the possible
display range of
1
£ (C1223 × C1205) £ 1.07E9 inc
Check the values in C1202/4,
C1207/1, C1207/2. Read out the
limited value in C1220/10 and
enter it in C1223 if necessary.
C1298 = 2:
The positive position limit in
C1224 is outside the possible
display range of
1
£ (C1224 × C1205) £ 1.07E9 inc
Check the values in C1202/4,
C1207/1, C1207/2. Read out the
limited value in C1220/11 and
enter it in C1224 if necessary.
C1298 = 3:
The maximum speed v
max
in
C1240 is outside the possible
display range of
1
£ (C1240 × C1205 ×
16.384)
£ 2.14E9 inc or v
max
not
C1240 / C1204 Ч 60
£ 1.5 Ч n
max
Check the values in C0011,
C1202/4, C1207/1, C1207/2. Read
out the limited value in C1220/12
and enter it in C1240 or adjust the
value in C1240 to C0011 if
necessary.
C1298 = 4:
The maximum acceleration a
max
in C1250 is outside the possible
display range of
1
£ (C1250 × C1205 × 16.384 / 10
00)
£ 2.8634E7 inc
Check the values in C1202/4,
C1207/1, C1207/2. Read out the
limited value in C1220/13 and
enter it in C1250 if necessary.
C1298 = 5:
An internal value range has been
exceeded for a speed
standardisation. Valid range:
1
£ (C0011 × C1207/1 / C1207/2
65536 / 60000)
£ 32767
Check the values in C0011,
C1207/1, C1207/2 and correct
them.