beautypg.com

Troubleshooting and fault elimination, System error messages general error messages – Lenze EVS9332xP User Manual

Page 399

background image

Troubleshooting and fault elimination

System error messages

General error messages

9

9.3

9.3.1

l

9.3−7

EDSVS9332P EN 5.0−07/2013

Remedy

Cause

Description

Fault message

Remedy

Cause

Description

Display

No.

x166

P16

Faulty transfer of system bus
(CAN) sync telegram.

The sync telegram from the
master (PLC) is out of sync cycle.

l

Set the "sync cycle" to the
transmission cycle of the
master (PLC) under C1121.

l

Note:
– C0362 displays the time

interval between 2 sync
telegrams.

– C0362 = 0: communication

interrupted.

The sync telegram of the master
(PLC) is not received.

l

Check communication channel.

l

Check baud rate, controller
address.

l

Note:
– C0362 displays the time

interval between 2 sync
telegrams.

– C0362 = 0: communication

interrupted.

The controller is enabled too fast.

Delay the controller enable.
The time delay required depends
on the time interval between the
sync telegrams.

x167

P17

Error "touch probe control".

Various function blocks use the
touch probe input at the same
time (e.g. FB DFSET and POS). A
conflict arises.

l

Configure another touch probe
input for FB POS (not possible
for FB DFSET).

l

Switch off monitoring
(C1289/1).

x168

P18

Internal limitation.

Arithmetic operation generated
data cannot be varied arbitrarily.
Wrongly specified values were
automatically limited internally.
C1298 = 1:
The negative position limit in
C1223 is outside the possible
display range of
1

£ (C1223 × C1205) £ 1.07E9 inc

Check the values in C1202/4,
C1207/1, C1207/2. Read out the
limited value in C1220/10 and
enter it in C1223 if necessary.

C1298 = 2:
The positive position limit in
C1224 is outside the possible
display range of
1

£ (C1224 × C1205) £ 1.07E9 inc

Check the values in C1202/4,
C1207/1, C1207/2. Read out the
limited value in C1220/11 and
enter it in C1224 if necessary.

C1298 = 3:
The maximum speed v

max

in

C1240 is outside the possible
display range of
1

£ (C1240 × C1205 ×

16.384)

£ 2.14E9 inc or v

max

not

C1240 / C1204 Ч 60

£ 1.5 Ч n

max

Check the values in C0011,
C1202/4, C1207/1, C1207/2. Read
out the limited value in C1220/12
and enter it in C1240 or adjust the
value in C1240 to C0011 if
necessary.

C1298 = 4:
The maximum acceleration a

max

in C1250 is outside the possible
display range of
1

£ (C1250 × C1205 × 16.384 / 10

00)

£ 2.8634E7 inc

Check the values in C1202/4,
C1207/1, C1207/2. Read out the
limited value in C1220/13 and
enter it in C1250 if necessary.

C1298 = 5:
An internal value range has been
exceeded for a speed
standardisation. Valid range:
1

£ (C0011 × C1207/1 / C1207/2

65536 / 60000)

£ 32767

Check the values in C0011,
C1207/1, C1207/2 and correct
them.

This manual is related to the following products: